Choosing an industrial sensor should not begin with a catalogue.

It should begin with the application.

A reliable sensor system is created when the target, environment, electrical signal, connector, PLC and maintenance requirements are considered together.

Too often, a plant selects a sensor that appears correct technically but discovers problems only after installation.

The sensor may detect the target but produce the wrong output for the PLC. The sensing distance may work when the machine is stationary but become unreliable when the product vibrates. The sensor may have the right IP rating but be connected through an unsuitable connector.

Building a complete industrial sensor solution means considering the entire path:

Process → Sensor → Cable/Connector → PLC → Logic → Feedback → Operator

For South African manufacturers, mining operations, packaging plants, process facilities and OEM machine builders, this systems-based approach can improve reliability and reduce troubleshooting.

Step 1: Define exactly what needs to be detected or measured

Before choosing technology, define the task.

Are you trying to:

  • Detect a product?
  • Count items?
  • Measure speed?
  • Confirm position?
  • Monitor pressure?
  • Detect flow?
  • Measure tank level?
  • Monitor temperature?
  • Track humidity?
  • Measure vibration?

Different requirements need different sensing technologies.

A proximity sensor is not a pressure sensor. A speed sensor does not solve a level application. Even within one product category, different technologies may suit different targets.

Start with the process question.

Step 2: Understand the target or media

For detection applications, define the target.

Consider:

  • Metal or non-metal?
  • Solid or liquid?
  • Opaque or transparent?
  • Reflective?
  • Hot?
  • Wet?
  • Moving?
  • Irregularly shaped?

For process sensors, define the media:

  • Air
  • Water
  • Oil
  • Chemical
  • Powder
  • Steam
  • Other process media

This narrows the product selection significantly.

Step 3: Select the sensing technology

Proximity: Useful for many non-contact metal-detection and machine-position applications. https://switches.co.za/product-category/proximity/

Optical: Useful for product presence, cartons, bottles, packaging and many conveyor applications. https://switches.co.za/product-category/optical/

Limit switches: Useful for mechanical position confirmation. https://switches.co.za/product-category/limit/

Pressure: Useful for pressure and vacuum monitoring. https://switches.co.za/product-category/pressure-vacuum-sensors-switches/

Flow

Air: https://switches.co.za/product-category/flow-air/

Liquid: https://switches.co.za/product-category/flow-liquid/

Level: https://switches.co.za/product-category/level/

Temperature: https://switches.co.za/product-category/temperature/

Speed: https://switches.co.za/product-category/speed/

Rotary encoders: https://switches.co.za/product-category/rotary-encoders/

Switches International’s current product range covers these broad sensing and automation families, supporting a multi-category solution approach rather than a single-sensor focus.

Step 4: Determine sensing distance or measurement range

A sensor should operate comfortably within the application’s real working range.

For proximity detection, consider:

  • Nominal sensing distance
  • Target movement
  • Alignment tolerance
  • Mechanical vibration

For measurement sensors, define:

  • Minimum expected value
  • Normal range
  • Maximum value
  • Possible abnormal conditions

Do not specify a sensor based only on the normal condition if the process can exceed it.

Step 5: Confirm the electrical output

This is where apparently correct sensors often become incompatible.

The PLC needs to receive a signal it understands.

For discrete sensors, output options may involve PNP or NPN logic.

For process measurement, common signals include:

  • 4–20mA
  • 0–10V
  • Pulse
  • Switching outputs
  • Device-specific digital interfaces

Switches International’s PLC integration guidance specifically emphasises matching PNP/NPN sensor outputs to PLC inputs and checking wiring, common references and connector pinouts.

Before ordering, confirm:

  • PLC model
  • Input type
  • Supply voltage
  • Signal type
  • Number of wires
  • Connector configuration

Step 6: Treat the connector as part of the sensor

A sensor without a reliable electrical connection cannot create reliable automation.

Connector selection should consider:

  • Pinout
  • Cable length
  • Straight or angled format
  • Environmental rating
  • Flexing
  • Vibration
  • Moisture
  • Electrical noise
  • Maintenance access

Cable Connectors: https://switches.co.za/product-category/cable-connectors/

Standardising connectors where possible can simplify replacements.

Step 7: Match the environmental rating

Ask where the sensor will live.

Is the area:

  • Dusty?
  • Wet?
  • Outdoors?
  • Exposed to washdown?
  • Hot?
  • Cold?
  • Vibrating?
  • Chemically aggressive?

Do not assume an indoor factory is a mild environment. Equipment near conveyors, cooling systems, washdown lines or process machinery may experience highly localised conditions.

Select the sensor, connector and cabling for the real installation.

Step 8: Consider signal noise

Industrial machinery contains motors, variable-frequency drives, contactors and other equipment capable of creating electrical interference.

Signals – particularly low-level, pulse or analogue measurements – may require careful cable routing and shielding.

General good practice can include:

  • Separating signal and high-power wiring
  • Using appropriate screened cable where required
  • Correct grounding
  • Avoiding unnecessary cable loops
  • Following manufacturer installation guidelines

If a sensor changes state correctly at the device but the PLC input behaves inconsistently, the signal path should be investigated.

Step 9: Decide whether local display is required

Not all sensor information needs to exist only inside a PLC.

Local displays can help:

  • Operators
  • Commissioning engineers
  • Maintenance technicians
  • Production supervisors

For example:

  • Displaying conveyor speed
  • Showing pressure
  • Viewing flow
  • Counting units
  • Displaying RPM
  • Comparing two process values

Electronic display/controllers: https://switches.co.za/product-category/electronic-display-controllers/

JR-D 6-Digits: https://switches.co.za/product/jr-d-6-digits/

Kappa-M Dual Input: https://switches.co.za/product/kappa-m-dual-input/

Step 10: Design for maintenance

A technically correct installation can still be difficult to maintain.

Ask:

  • Can the sensor be reached?
  • Can it be adjusted safely?
  • Is the connector accessible?
  • Is the part number visible?
  • Is the cable labelled?
  • Can the replacement be installed without major dismantling?
  • Is a spare available?

Maintenance should be considered during the original design.

Step 11: Build a spares strategy

Critical components deserve planned replacement stock.

Document:

  • Sensor model
  • Location
  • Function
  • Output
  • Connector
  • Voltage
  • Replacement option
  • Criticality

This prevents the plant from starting the specification process from zero every time a component fails.

Step 12: Commission the complete signal path

Do not stop testing when the sensor LED changes.

Commissioning should confirm that the entire chain works.

For a detection sensor:

  1. Present the actual target.
  2. Confirm sensor operation.
  3. Confirm electrical output.
  4. Confirm PLC input.
  5. Confirm PLC logic.
  6. Confirm machine response.
  7. Repeat under realistic production conditions.

For analogue measurement:

  1. Verify sensor reading.
  2. Check signal.
  3. Confirm PLC scaling.
  4. Compare displayed engineering value.
  5. Test relevant alarm or control points.

This catches integration issues before full production.

Example: conveyor product detection

Suppose a packaging conveyor must detect cartons.

The design process might be:

Application: Product presence
Target: Cardboard carton
Technology: Optical sensor
Environment: Dusty production area
Distance: 500 mm example working position
Output: Must match PLC input
Connector: Industrial quick-disconnect
Logic: Product detected triggers counting event
Maintenance: Sensor lens accessible for cleaning
Spare: Matching replacement stored on site

The finished solution is therefore much more than the sensor.

Example: conveyor speed monitoring

For conveyor speed:

Application: Monitor belt/shaft speed
Sensor: Speed sensor or rotary encoder
Input: Pulse signal
Display: Optional JR-D / controller
PLC: High-speed or compatible pulse input where required
Environment: Dust/vibration considered
Maintenance: Sensor gap and mounting documented

Speed Sensors: https://switches.co.za/product-category/speed/

Rotary Encoders: https://switches.co.za/product-category/rotary-encoders/

Switches International currently positions its rotary encoders for industrial motion detection including conveyor and motor feedback applications.

Building sensor systems for South African industry

South African operations often contain equipment installed over many years.

A single plant may have:

  • New PLC-controlled production equipment
  • Older machines
  • Imported machinery
  • Different sensor brands
  • Several connector standards
  • Obsolete components

A complete-solution approach helps rationalise this environment.

It allows maintenance teams to consider:

  • Standardised outputs
  • Common connectors
  • Product availability
  • Replacement equivalents
  • Critical spares
  • Local support

This can be valuable in manufacturing centres such as Gauteng, KwaZulu-Natal and the Western Cape, as well as mining and process operations across the country.

Recommended Products:

FAQs

What information should I provide when asking for an industrial sensor recommendation?

Provide the target or media, sensing/measurement range, environment, PLC input, required output, supply voltage and connector requirements.

The PLC input must be electrically compatible with the signal produced by the sensor. Otherwise, the sensor may operate but the PLC may not register it correctly.

Connectors form part of the signal path. Poor connector selection or installation can cause intermittent or complete signal failure.

Provide the existing part number, specifications and application details so suitable alternatives can be assessed.

No. Critical sensors should also form part of ongoing inspection and preventative-maintenance routines.

Build the complete sensor solution – not just the sensor.

Send Switches International your:

  • Application
  • Target or media
  • Required sensing range
  • Environment
  • PLC model/input
  • Existing sensor details
  • Connector requirement.